Technical values are transcribed from the current ATTACK product page and the 2026 ATTACK catalogue, page 33. Some values in the catalogue table apply to more than one output; models 12–20 have 3 sections and models 25–30 have 4. The page states 93% efficiency in its marketing copy and 92–93% in the technical table.
| Parameter | Unit | 12 | 15 | 20 | 25 | 30 |
|---|---|---|---|---|---|---|
| Rated output of EKO and KLV | kW | 12 | 15 | 20 | 25 | 30 |
| Rated heat input of EKO and KLV | kW | 13.4 | 16.5 | 19.5 | 27 | 32.5 |
| Number of sections | pcs | 3 | 3 | 3 | 4 | 4 |
| Controllable output of PLQ and KLQ | kW | — | 12–15 | 14.5–18 | 20–25 | 24–30 |
| Modulating output of E and EZ | kW | — | 12–15 | 14.5–18 | 20–25 | 24–30 |
| Controllable heat input of PLQ and KLQ | kW | — | 13.5–16.5 | 15.6–19.5 | 21.6–27 | 26.4–32.5 |
| Modulating heat input of E and EZ | kW | — | 13.5–16.5 | 15.6–19.5 | 21.6–27 | 26.4–32.5 |
| Nozzle diameter | mm | 2.5 | 2.5 | 2.5 | 2.5 | 2.7 |
| Nozzle pressure for EKO, PLQ and KLQ | kPa | 0.8 | 0.8–1.05 | 1.05–1.45 | 0.8–1.2 | 0.9–1.25 |
| Nozzle pressure for E and EZ | kPa | — | 0.8–1.05 | 1.05–1.45 | 0.8–1.2 | 0.9–1.25 |
| Gas consumption at maximum output | m³/h | 1.3 | 1.6 | 2.05 | 2.65 | 3.15 |
| Gas consumption at minimum output | m³/h | — | 1.25 | 1.65 | 2.1 | 2.5 |
| NOx class | — | 5 | 5 | 5 | 5 | 5 |
| Fuel | — | Natural gas G 20 | Natural gas G 20 | Natural gas G 20 | Natural gas G 20 | Natural gas G 20 |
| Natural gas connection | DN | 15 (union nut 3/4") | 15 (union nut 3/4") | 15 (union nut 3/4") | 15 (union nut 3/4") | 15 (union nut 3/4") |
| Flue-gas outlet diameter | mm | 110 | 110 | 110 | 135 | 135 |
| Water capacity of cast-iron body | l | 10 | 10 | 10 | 13.8 | 13.8 |
| Maximum pressure in heating circuit | kPa | 300 | 300 | 300 | 300 | 300 |
| Heating-circuit connection | G | 3/4" | 3/4" | 3/4" | 3/4" | 3/4" |
| Boiler weight | kg | 99 | 99 | 99 | 125 | 125 |
| Electrical supply | V/Hz | ~230/50 | ~230/50 | ~230/50 | ~230/50 | ~230/50 |
| Ingress protection rating | IP | 40 | 40 | 40 | 40 | 40 |
| Heating-water temperature | °C | 40–90 | 40–90 | 40–90 | 40–90 | 40–90 |
| Efficiency | % | 92–93 | 92–93 | 92–93 | 92–93 | 92–93 |
| Flue-gas mass flow | g/s | — | 14.4 | — | 20.5 | — |
| Electrical input | W | 15–30 | 15–30 | 15–30 | 15–30 | 15–30 |