For the home
Suitable for many types of home
This high-output, efficient solid-fuel boiler can suit many types of home. Eligible households in Slovakia may also receive support through the Green for Households programme.

30 years of development and manufacturing
ATTACK DPX PELLET combines the DPX boiler design with PROFI controls and an automatic burner. A screw feeder moves pellets from the hopper to the burner, where they are ignited electrically and the burner cleans itself automatically.
Category: Pellet boilers
Explore the ATTACK DPX PELLET pellet boiler
Choose a topic to learn more about the ATTACK DPX PELLET, its installation and everyday operation.
Automatic operation

ATTACK DPX PELLET technical features
Explore fuel feeding, the burner, controls and safety features.
ATTACK DPX PELLET boiler options
Technical features presented as practical benefits for system design, installation and everyday use.
Interactive component map
Select a marker on the cutaway to learn what each boiler component does.
Detailed specifications
Check the manufacturer's current documentation before designing the heating system.
| Parameter | Unit | 25DPXPE | 30DPXPE | 35DPXPE | 40DPXPE | 45DPXPE | 50DPXPE |
|---|---|---|---|---|---|---|---|
| Nominal boiler output | kW | 30 | 30 | 30 | 40 | 45 | 49.9 |
| Output range | kW | 8–30 | 8–30 | 8–30 | 15–49.9 | 15–49.9 | 15–49.9 |
| Heat exchanger surface area | m² | 2.52 | 2.78 | 2.78 | 3.03 | 3.03 | 3.03 |
| Combustion chamber volume | l | 125 | 158 | 158 | 190 | 190 | 190 |
| Upper door opening dimensions | mm | 235 × 445 | 235 × 445 | 235 × 445 | 235 × 445 | 235 × 445 | 235 × 445 |
| Required chimney draught | Pa | 23 | 23 | 23 | 23 | 23 | 23 |
| Maximum operating water pressure | kPa | 250 | 250 | 250 | 250 | 250 | 250 |
| Water-side pressure drop (ΔT 10 K) | kPa | 2.3 | 4.4 | 4.4 | 6.6 | 6.6 | 6.6 |
| Water-side pressure drop (ΔT 20 K) | kPa | 0.7 | 1 | 1 | 1.8 | 1.8 | 1.8 |
| Boiler weight | kg | 480 | 510 | 510 | 540 | 540 | 540 |
| Flue outlet diameter | mm | 150 | 150 | 150 | 150 | 150 | 150 |
| Boiler height | mm | 1 237 | 1 237 | 1 237 | 1 237 | 1 237 | 1 237 |
| Boiler width | mm | 791 | 791 | 791 | 791 | 791 | 791 |
| Boiler depth with burner | mm | 1 527 | 1 570 | 1 570 | 1 818 | 1 818 | 1 818 |
| Lower burner height – J | mm | 682 | 682 | 682 | 695 | 695 | 695 |
| Upper burner height – K | mm | 968 | 968 | 968 | 960 | 960 | 960 |
| Pellet feed centre-line height – L | mm | 1 109 | 1 109 | 1 109 | 1 103 | 1 103 | 1 103 |
| Boiler depth with door cover, without burner | mm | 1 287 | 1 332 | 1 332 | 1 505 | 1 505 | 1 505 |
| Horizontal flue position – D | mm | 980 | 980 | 980 | 980 | 980 | 980 |
| Vertical flue position – E | mm | 1 037 | 1 037 | 1 037 | 1 037 | 1 037 | 1 037 |
| Fan height – F | mm | 758 | 758 | 758 | 758 | 758 | 758 |
| Return connection position – G | mm | 292 | 292 | 292 | 366 | 366 | 366 |
| Cooling loop position – H | mm | 284 | 284 | 284 | 352 | 352 | 352 |
| Combustion chamber depth | mm | 590 | 690 | 690 | 790 | 790 | 790 |
| Electrical protection rating | IP | 21 | 21 | 21 | 21 | 21 | 21 |
| Electrical input during ignition | W | 600 | 600 | 600 | 600 | 600 | 600 |
| Electrical input during operation | W | 96 | 160 | 160 | 190 | 190 | 190 |
| Electrical input in standby | W | <5 | <5 | <5 | <5 | <5 | <5 |
| Boiler efficiency | % | 90.8 | 90.5 | 90.2 | 90.6 | 90.5 | 90.2 |
| Boiler class | 5 | 5 | 5 | 5 | 5 | 5 | |
| Flue-gas temperature at rated output | °C | 145 | 152 | 168 | 148 | 155 | 164 |
| Flue-gas temperature at minimum output | °C | 109 | 116 | 129 | 110 | 119 | 126 |
| Flue-gas mass flow at rated output | kg/s | 0.018 | 0.020 | 0.022 | 0.025 | 0.028 | 0.029 |
| Flue-gas mass flow at minimum output | kg/s | 0.005 | 0.007 | 0.009 | 0.012 | 0.014 | 0.015 |
| Maximum noise level | dB | 65 | 65 | 65 | 65 | 65 | 65 |
| Specified fuel | — | Wood pellets, Ø 6 mm, maximum length 35 mm, moisture content up to 12%; DIN 51 731–HP 5, DINplus, EN 14961-2–A1 | Wood pellets, Ø 6 mm, maximum length 35 mm, moisture content up to 12%; DIN 51 731–HP 5, DINplus, EN 14961-2–A1 | Wood pellets, Ø 6 mm, maximum length 35 mm, moisture content up to 12%; DIN 51 731–HP 5, DINplus, EN 14961-2–A1 | Wood pellets, Ø 6 mm, maximum length 35 mm, moisture content up to 12%; DIN 51 731–HP 5, DINplus, EN 14961-2–A1 | Wood pellets, Ø 6 mm, maximum length 35 mm, moisture content up to 12%; DIN 51 731–HP 5, DINplus, EN 14961-2–A1 | Wood pellets, Ø 6 mm, maximum length 35 mm, moisture content up to 12%; DIN 51 731–HP 5, DINplus, EN 14961-2–A1 |
| Minimum/maximum fuel consumption | kg/h | 2.4 / 6.9 | 2.4 / 6.9 | 2.4 / 6.9 | 3.4 / 12.5 | 3.4 / 12.5 | 3.4 / 12.5 |
| Boiler water volume | l | 100 | 110 | 110 | 128 | 128 | 128 |
| Recommended buffer tank volume | l | 300 | 300 | 300 | 300 | 300 | 300 |
| Supply voltage | V/Hz | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 |
| Minimum return water temperature | °C | 65 | 65 | 65 | 65 | 65 | 65 |
| Heating water temperature setting range | °C | 65–90 | 65–90 | 65–90 | 65–90 | 65–90 | 65–90 |
| Controller contact rating | V/A | 230/2 | 230/2 | 230/2 | 230/2 | 230/2 | 230/2 |
| Heating-system connection – A, B | G 6/4″ | G 6/4″ | G 6/4″ | G 2″ | G 2″ | G 2″ |
Product materials
Customer service
Find manuals, technical support and a service partner for your ATTACK DPX PELLET boiler.
Go to service assistanceNeed advice?