The floor-standing enamelled tank has two heat exchangers and is designed for connection to a solar system and a condensing gas boiler or biomass boiler. It is available in 200 and 300 litre capacities.

Variants
  • Z 200 SOL
  • Z 300 SOL

Category: Domestic hot water tanks

Enamelled steelMaterial
LowHeat loss
For gas and biomass boilers
Robot-weldedHigh-precision welding

Solar systems and boilers

Tank for multiple heat sources

ATTACK Z SOL is suitable for a solar system, a condensing gas boiler and a biomass boiler. The two heat exchangers allow heat sources to be combined to suit the heating system design.
ATTACK Z 200/300 SOL enamelled tank

Detailed connection diagram

Inlets, outlets and connections for the Z SOL tank

The diagram identifies the DHW connection, upper and lower heat exchangers, electric element, circulation line and sensors.

Inlets, outlets and connections for the Z SOL tank
Connection diagram for the ATTACK Z 200/300 SOL tank

Komponent H / 11

Thermometer connection

H in the diagram: thermometer connection.

Komponent FE / 11

Upper electric heating element

FE in the diagram: upper electric heating element.

Komponent MV / 11

Heat outlet

MV in the diagram: heat outlet.

Komponent FHB / 11

Upper heat-exchanger inlet

Heating-medium inlet for the upper heat exchanger.

Komponent FHE / 11

Upper heat-exchanger sensor

Sensor pocket for the upper heat exchanger.

Komponent C / 11

Circulation line

C in the diagram: circulation line.

Komponent FHK / 11

Upper heat-exchanger outlet

Heating-medium outlet for the upper heat exchanger.

Komponent AHB / 11

Lower heat-exchanger inlet

Heating-medium inlet for the lower heat exchanger.

Komponent AHE / 11

Lower heat-exchanger sensor

Sensor pocket for the lower heat exchanger.

Komponent AHK / 11

Lower heat-exchanger outlet

Heating-medium outlet for the lower heat exchanger.

Komponent HV / 11

Tank inlet

HV in the diagram: tank inlet.

Detailed specifications

Technical data

Check the manufacturer's current documentation before designing the heating system.

ParameterUnitZ 200 SOLZ 300 SOL
Nominal capacityl200300
Rated operating pressureMPa0.60.6
Maximum safety-valve opening pressureMPa0.70.7
Minimum required water pressureMPa0.010.01
Standby energy consumption at 65 °CWh/24 h19002500
Heated volume of the lower heat exchangerl200300
Area of the lower heat exchangerm²0.81.0
Volume of the lower heat exchangerl5.58.3
Operating pressure of the lower heat exchangerMPa0.60.6
Heated volume of the upper heat exchangerl90130
Area of the upper heat exchangerm²0.6150.7
Volume of the upper heat exchangerl4.14.6
Operating pressure of the upper heat exchangerMPa0.60.6
Tank material—Enamelled steel sheetEnamelled steel sheet
Heat-exchanger material—Enamelled steel tubeEnamelled steel tube
Corrosion protection—Fired enamel + active anodeFired enamel + active anode
Cold and hot water connection—G3/4G3/4
Circulation line—G3/4G3/4
Provision for an electric heating element—Rp6/4Rp6/4
Heat-exchanger connection—Rp3/4Rp3/4
Thermometer and sensor connection—Rp1/2Rp1/2

Product materials

Download documents

Customer service

Installation support

ATTACK service partners provide professional help with installation and operation. Ask a qualified partner to check the system design.

Service support

Need advice?

Choose a tank for a solar system and boiler

When designing the system, consider hot-water demand, the solar circuit and the auxiliary heat-source connection.

Request a free quote