ATTACK DPX 15 wood boiler

Compact dimensions. Easier installation.

ATTACK DPX 15 is a wood gasification boiler rated at 15 kW and designed to burn logs. Its compact design makes it easier to install in a smaller boiler room. The 82-litre loading chamber accepts logs up to 350 mm long.

Category: Wood boilers

91.3%efficiency in the technical table
Gravity circulationG2
350 mmmaximum log length
Class 5emission class

Compact dimensions of the ATTACK DPX 15 boiler

Easier installation in a smaller boiler room

Compact dimensions and improved access to the electrical connections make the boiler easier to position. When selecting the output, consider the chimney height and cross-section as well as the heating system. The manufacturer recommends discussing the design with a service technician, chimney professional or heating-system designer.
Compact dimensions of the ATTACK DPX 15 boiler

Technical information about boiler components

Explore the key components of ATTACK DPX 15

This interactive map shows a cutaway of the ATTACK DPX boiler. Select a marker to see what each component does.

Explore the key components of ATTACK DPX 15
Cutaway view of the ATTACK DPX boiler with marked components

Komponent 01 / 10

Control panel

The product page lists three control electronics options. The basic control is intended for simple systems; STANDARD and PROFI versions offer additional settings.

Komponent 02 / 10

Turbulators

Turbulators in the tubular heat exchanger improve heat transfer. The exchanger can be cleaned with a mechanical lever.

Komponent 03 / 10

Refractory concrete nozzle

The refractory concrete nozzle supports reliable combustion and, according to the product page, withstands temperatures up to 1,350 °C.

Komponent 04 / 10

Loading-chamber door

Logs are loaded through the upper door. The DPX 15 chamber holds 82 litres and accepts logs up to 350 mm long.

Komponent 05 / 10

Turbulator cleaning lever

The lever mechanically cleans the tubular heat exchanger. The manufacturer says it can be positioned on either side.

Komponent 06 / 10

Cleaning access

The opening provides access to the heat exchanger for cleaning.

Komponent 07 / 10

Fan

The ATTACK DPX 15 gasification boiler includes an induced-draught fan.

Komponent 08 / 10

Cooling loop

The cooling loop is part of the boiler’s hydraulic equipment.

Komponent 09 / 10

Automatic flue damper

When lighting the boiler or adding logs, it directs flue gas from the loading chamber straight to the chimney. It closes automatically when the loading door is shut.

Komponent 10 / 10

Combustion-chamber door

The lower door is used to remove ash. With the PROFI version, it also allows manual adjustment of the air supply.

Detailed specifications

Technical data

The technical table on the Slovak product page lists efficiency at 91.3%; accompanying text gives 91% and up to 92%. The product page and manual state a minimum buffer tank volume of 400 l and a recommended volume of 800 l; the DPX 15 information sheets state a 600 l minimum. The table retains the product-page values, and these discrepancies are noted for verification.

ParameterUnitDPX15
Rated boiler output (STANDARD version)kW15
Output range (PROFI version)kW7.5 – 15
Heat exchanger surface aream²1.98
Loading chamber volumedm³82
Loading door dimensionsmm235 × 445
Required chimney draughtPa23
Maximum operating water pressurekPa250
Water-side pressure drop (ΔT 10 K)kPa1.9
Water-side pressure drop (ΔT 20 K)kPa0.6
Boiler weightkg370
Flue outlet diametermm150
Boiler height – Amm1 240
Boiler width – Bmm702
Boiler depth – Cmm1 000
Loading chamber depth – Dmm400
External thread diameter of flow connection – E″G 2
External thread diameter of return connection – F″G 2
Cooling loop position – Gmm507
Flow connection position – Hmm778
Ingress protection ratingIP21
Electrical inputW32
Boiler efficiency%91.3
Boiler class by CO emissions (EN 303-5)—5
Flue-gas temperature at rated output°C170
Flue-gas mass flow at rated outputkg/s0.019
Maximum noise leveldB65
Fuel—Logs with 12–20% moisture content, 80–150 mm diameter
Average fuel consumptionkg/h3.9
Estimated seasonal consumption—1 kW = 0,9 m³
Maximum log lengthmm350
Burn time at rated outputh3
Boiler water volumel80
Minimum buffer tank volume according to the product tablel400
Recommended buffer tank volumel800
Supply voltageV/Hz~230/50
Heating water temperature setting range°C65–90
Room temperature setting range (PROFI version)°C10–27
Boiler controller contact rating (PROFI version)A/V2 A / 230 V
Maximum A-weighted sound pressure leveldB(A)70
Maximum C-weighted peak sound pressure levelPa63
Minimum return water temperature°C65
Boiler operating water temperature°C80–90

Product materials

Download documents

Customer service

Service assistance for ATTACK DPX 15

Find a service partner, documents and technical support for your boiler. For installation, maintenance and spare parts, contact a trained service technician.

Go to service assistance

Need advice?

Not sure which model is right for you? We can help.

Discuss the boiler output, chimney and heating-system connections with our technical team.

Request a free quote