30 years of development and production

ATTACK SLX wood boiler

Large chamber. 20 to 55 kW output.

ATTACK SLX is an emission class 5 wood-gasification boiler for logs. It is available in output models from 20 to 55 kW and with a 200 to 230 litre chamber. The LAMBDA Touch version automatically controls the air supply and heat-exchanger cleaning.
Model
  • SLX20
  • SLX25
  • SLX30
  • SLX35
  • SLX40
  • SLX45
  • SLX50
  • SLX55
Control system
  • PROFI
  • LAMBDA Touch
Emission class
  • 5

Category: Wood boilers

20–55 kWoutput models
up to 92%efficiency stated on the product page
200–230 lloading chamber volume
Class 5emission class

ATTACK SLX boiler features

A solution for the most demanding customers

ATTACK SLX brings comfort and output for people who expect more from their heating system. The LAMBDA Touch version automatically controls the air supply and cleans the turbulators; an internet connection also lets you control the boiler remotely. Combustion efficiency of up to 92% helps reduce fuel use and heating costs. The large loading chamber also saves time when preparing wood.
ATTACK SLX wood boiler with a buffer tank

Boiler construction

Explore the ATTACK SLX boiler components

Select a point on the cutaway diagram to learn what each boiler component does.

Explore the ATTACK SLX boiler components
Cutaway diagram of the ATTACK SLX boiler with labelled components

Komponent 01 / 12

Lambda sonda

It monitors oxygen levels in the flue gases and sends the controller data to manage combustion in the LAMBDA Touch version.

Komponent 02 / 12

Control panel

The boiler is available with PROFI controls, which allow manual air adjustment, or LAMBDA Touch, which automatically controls the air supply and heat-exchanger cleaning.

Komponent 03 / 12

Turbulators

The moving turbulators improve heat transfer in the exchanger; LAMBDA Touch cleans them automatically.

Komponent 04 / 12

Refractory concrete nozzle

The refractory concrete nozzle withstands temperatures up to 1,350 °C and supports reliable operation.

Komponent 05 / 12

Dry jacket

The dry jacket creates a thermal barrier in the loading chamber and helps prevent tar deposits.

Komponent 06 / 12

Dvierka nakladacej komory

Logs are loaded through the upper door. Chamber volume and maximum log length depend on the output model.

Komponent 07 / 12

Turbulator lever

With PROFI controls, the turbulators are cleaned with a manual lever; LAMBDA Touch uses a servomotor.

Komponent 08 / 12

Cleaning opening

The side opening allows ash to be removed from the turbulator area.

Komponent 09 / 12

Combustion chamber door

The lower door lets you remove ash from the combustion chamber and, with PROFI controls, adjust the air supply.

Komponent 10 / 12

Fan

The induced-draught fan creates the airflow needed to maintain boiler output.

Komponent 11 / 12

Cooling loop

It helps cool the heat exchanger if the safety temperature is reached.

Komponent 12 / 12

Flue-gas extraction channel

The extraction channel removes flue gases while fuel is being loaded into the chamber.

Detailed specifications

Technical data

The accompanying Slovak product-page text gives log lengths of 690 and 790 mm, while its technical table and manual list maximum lengths of 650 and 750 mm; the table is retained. The advertised efficiency of up to 92% reflects rounding of the highest table value, 91.8%. Burn time depends on the fuel and how full the chamber is.

ParameterUnitSLX20SLX25SLX30SLX35SLX40SLX45SLX50SLX55
Nominal boiler outputkW2025303540455055
Output rangekW10 – 2012.5 – 2515 – 3017.5 – 3520 – 4022.5 – 4525 – 5027.5 – 55
Heat exchanger surface aream²2.952.952.952.953.323.323.323.32
Loading chamber volume without dry jacketsdm³200200200200230230230230
Rozmer plniaceho otvorumm235 × 445235 × 445235 × 445235 × 445235 × 445235 × 445235 × 445235 × 445
Required chimney draughtPa2323232323232323
Required chimney draughtmbar0.230.230.230.230.230.230.230.23
Maximum water operating pressurekPa250250250250250250250250
Water-side pressure drop (ΔT 10 K)kPa1.92.12.42.73.94.55.26.1
Water-side pressure drop (ΔT 20 K)kPa0.80.91.21.61.92.12.43.2
Boiler weightkg570570570570650650650650
Flue outlet diametermm150150150150150150150150
Boiler heightmm14721472147214721472147214721472
Boiler widthmm703703703703703703703703
Boiler depthmm13371337133713371506150615061506
Loading chamber depthmm650650650650750750750750
Flow connection diameter — E″G 6/4G 6/4G 6/4G 6/4G 2G 2G 2G 2
Return connection diameter — F″G 6/4G 6/4G 6/4G 6/4G 2G 2G 2G 2
Ingress protection ratingIP2121212121212121
Electrical input at nominal outputW4242424278787878
Electrical input at minimum outputW3131313152525252
Standby electrical inputW< 15< 15< 15< 15< 15< 15< 15< 15
Boiler efficiency%91.891.690.390.390.490.490.390.3
Boiler class—55555555
Flue-gas temperature at nominal output°C165170175180165170170180
Flue-gas temperature at minimum output°C130135140145135140140145
Flue-gas mass flow at nominal outputkg/s0.0180.020.0210.0230.0270.0290.0310.033
Flue-gas mass flow at minimum outputkg/s0.0080.0110.0140.0160.0170.0210.0220.023
Maximum noise leveldB6565656565656565
Fuel class and type—Class A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mmClass A logs with 12–20% moisture and a diameter of 50–150 mm
Average wood consumptionkg/h5.26.57.89.110.411.71314.3
Estimated wood consumption per season—1 kW = 1 m³1 kW = 1 m³1 kW = 1 m³1 kW = 1 m³1 kW = 1 m³1 kW = 1 m³1 kW = 1 m³1 kW = 1 m³
Maximum log lengthmm650650650650750750750750
Burn time at nominal outputh87.26.55.865.14.64
Objem vody v kotlel117117117117136136136136
Supply voltageV/Hz~230/50~230/50~230/50~230/50~230/50~230/50~230/50~230/50
Rozsah nastavenia teploty vykurovacej vody°C65 ÷ 8565 ÷ 8565 ÷ 8565 ÷ 8565 ÷ 8565 ÷ 8565 ÷ 8565 ÷ 85
PROFI controller contact rating—2 A/ ~230 V2 A/ ~230 V2 A/ ~230 V2 A/ ~230 V2 A/ ~230 V2 A/ ~230 V2 A/ ~230 V2 A/ ~230 V
Minimum buffer tank volumel5006007008001000110012001300
Recommended buffer tank volumel10001400160020002200250028003000

Product materials