Verified quality of products-attack-EN

30 years of tradition

Wall-mounted fancoil unit ATTACK FCU

Suitable for heat pumps

Category:

1,8-10,8 kW
Power

Comfortable temperature
all year round

3
Step modulation

Automatic
Flap rotation

Wall-mounted fancoil units with power from 1.8 – 10.8 kW are suitable for smaller spaces where they ensure a pleasant temperature all year round. It is precisely the heat pump as a source of heat and cold that can supply the fancoil with hot or cold water, which can be used during the summer for pleasant interior cooling and during the winter for providing heat at low costs.

Wall-mounted fan coil unit attack fcu1 en

Suitable for spaces where, for layout reasons, the use of another system (cassette) is not possible due to the structural height of the ceiling. As a rule, with the same power parameters, the wall-mounted unit is advantageous compared to the cassette unit, especially in price. Both solutions are qualitatively at the same level; it depends on the design possibilities according to the requirements of the given space.

Simple installation

Installing the unit is simple; just connect to the distribution pipes from the heat pump. Installation in existing spaces has minimal requirements for additional structural modifications.

Maximally utilized potential

The heat pump in the CH system can supply cold or hot water to the fancoil. Especially in the summer months, when hot weather can reach interiors, the fancoil ensures a comfortable temperature, which is essential for humans. In the winter months, the fancoil unit can become a better heat source than radiators due to low operating costs.

Main advantages

Automatic flap rotation

3

Three-step modulation

Differences

The difference between a cassette and a wall-mounted unit lies in the direction and distribution of air. The cassette unit distributes air in all directions with less intensity, while the wall-mounted unit distributes air in one direction with the full volume of air flow.

Remote control

Simple control using a controller offers several programs with the possibility of program timing. The fancoil unit can thus be set for certain hours of cooling or heating, which can be suitable specifically for timed house cooling when coming from work.

Using the remote control, it is possible to adjust intensity and direction of the cooling/heating air flow. The wall-mounted fancoil unit also offers the possibility of installing a fixed wired wall controller.

Heat pump cooling-en

Quality components with quiet operation

Efficient air flow, high degree of flow, and low unit noise, thanks to a well-positioned fan motor that operates with three-step power modulation and dampens vibrations.

Technical data and documents for download

The wall-mounted fancoil unit with its properties can effectively ensure a comfortable temperature in the house throughout the year. Find out more about other technical data.

loader-icon
  • Quiet operation
  • Automatic flap rotation into the space
  • Three-step modulation
  • Ensures pleasant temperature all year round
  • Power 1.8 – 10.8 kW
  • Suitable for ATTACK heat pumps
Model (two-pipe system) ATTACK FCU – W 2 ATTACK FCU – W 3 ATTACK FCU – W 4 ATTACK FCU – W 5 ATTACK FCU – W 6 ATTACK FCU – W 8
Power supply 220V / 50Hz 1 fáza
Air volume flow High m3/h 340 510 680 850 1020 1360
Medium 260 380 515 650 765 1010
Low 180 260 340 430 520 700
Static pressure Pa 0 0 0 0 0 0
Cooling capacity Total High W 1800 2700 3600 4500 5400 7200
Legible W 1350 2025 2700 3375 4050 5400
Total Medium W 1476 2214 2952 3690 4428 5904
Legible W 978 1399 1963 2409 3044 3926
Total Low W 1098 1647 2196 2745 3294 4392
Legible W 649 960 1355 1715 2060 2710
Heating power High W 2700 4050 5400 6750 8100 10800
Medium W 2146 3219 4293 5366 6439 8586
Low W 1512 2268 3024 3780 4536 6048
Noise level High 0Pa dB(A) 39 41 42 45 46 47
El. příkon High 0Pa W 50 52 60 75 95 130
Water flow m3/h 0,31 0,46 0,62 0,77 0,93 0,93
Pressure loss kPa 12 14 17 18 22,5 23,5
Water connection pipe size Input G1/2″ G1/2″ G1/2″ G1/2″ G1/2″ G1/2″
Exit G1/2″ G1/2″ G1/2″ G1/2″ G1/2″ G1/2″
Exchanger Type Highly efficient copper tube equipped with aluminum fins with hydrophilic (wetting) surface
Maximum pressure MPa 1,6 1,6 1,6 1,6 1,6 1,6
Condensate drain hose diameter G1/2″ G1/2″ G1/2″ G1/2″ G1/2″ G1/2″
Dimension L×W×H mm 850×300×198 850×300×198 970×315×235 970×315×235 1100×330×235 1100×330×235
Weight kg 11 11 15 15 20 20

Test conditions: 2-pipe system Cooling
Air inlet temperature: Dry thermometer 27ºC, Wet thermometer 19.5ºC

Inlet/outlet water temperature: 7ºC/ 12ºC

Heating
Inlet air temperature: 21ºC
Inlet water temperature: 60ºC, same water flow as for cooling

High-quality processing

All our products are manufactured with an emphasis on the selection of quality materials and the use of correct technologies and procedures. Quality components ensure maximum product reliability. Our own know-how is a guarantee of reliable service and long life.

fancoil unit attack quality production en

Choose a service partner

Creating a high-quality and prompt service network for our customers is very important to us. Our service partners provide prompt service assistance to every customer throughout the year.

We have a rich service network covering the entire territory of the world