Verified quality of products-attack-EN

30 years of tradition

Heat pump ATTACK Inverter R32

 

air/water monobloc type

Category:

-15 °C
Heating in winter

4,9
Seasonal SCOP factor

Mobile
Application

55 °C
Heating water temperature

The ATTACK heat pump represents a modern emission-free thermal energy source, which is based on the principle of obtaining energy from the surrounding air and transferring it to the hot water heating system. With maximum utilization of primary energy from the electricity grid, it produces the energy needed for heating/cooling or DHW heating.

heat pump attack house-en

An ideal solution for modern new buildings with energy class A0. High seasonal energy efficiency of heating A+++ saves costs even for renovated houses. The air/water heat pump system is the most investment-advantageous compared to other heat pump systems.

Simple installation

Installation can be performed by a heating engineer who does not need to be a refrigeration technician. For the monobloc type, only the heating circuit and electrical installation are connected. ATTACK INVERTER R32 consists of an outdoor and indoor unit. The monobloc outdoor unit contains all necessary components, facilitating installation and service. The indoor wall-mounted unit is the perfect solution in cases where you want to keep the existing hot drinking water preparation system or when you have limited space. The compact unit contains all necessary hydraulic connections, ensuring quick installation and simple maintenance.

How does an air-to-water heat pump work?

Find out how a monobloc air-to-water heat pump works and what its advantages are.

Heat pump air water attack-en

Complex system for a house with low noise

Modern technologies come with complex solutions for the household.
ATTACK heat pumps can control multiple temperature-independent heating circuits without the need for additional accessories or systems. Low noise level of the outdoor unit increases comfort. Inside, a noiseless indoor hydrounit with a touch display is installed for simple and very intuitive control of the entire system.

loader-icon
  • Centrally heating and cooling
  • Can control multiple temperature-independent heating circuits
  • Allows DHW preparation
  • Without the need for additional accessories or systems
We care about our customers’ satisfaction. Therefore, a WiFi router with the ATTACK Heating mobile application is an inseparable part of the heat pump. Control your device from any location.
All functional and moving parts of the device are installed in the outdoor unit outside the living part of the house.
Heat pumps offer a wide range of power. Single-propeller outdoor unit with power of 6, 9, and 12 kW and double-propeller with power of 15 and 19 kW.

Modern technologies with a multitude of functions

The heart of the device consists of a modern high-efficiency inverter compressor from the Mitsubishi brand. Heated refrigerant leaves the evaporator in gaseous form and is compressed by the compressor to a higher pressure and higher temperature, which is used in the condenser to transfer heat of the heating water into the household.

loader-icon
Mitsubishi high efficiency inverter compressor
In holiday mode, the heat pump works to maintain the minimum required temperature to save a maximum amount of energy and minimize heating costs. Via the mobile application, it is possible to keep the heat pump always under control. The mode also allows setting the start and end time of this period.
ATTACK heat pumps are equipped with a special Anti-Legionella function, which prevents the formation of harmful bacteria in the cylinder and DHW distribution.

Technical information on important parts of a heat pump that might interest you.

Heat pump-tech-infoen

Fan

It ensures the supply of air from which energy is taken from the evaporator.

Evaporator

It is used to absorb energy from the surrounding air.

Condensing exchanger

The energy is transferred from the refrigerant to the heating water In the condensing heat exchanger.

Compressor

It is a drive unit that serves to increase the pressure and temperature of the refrigerant in the heating circuit.

Refrigerant collector

It collects and captures the liquid form of refrigerant.

Electronic expansion valve

Ensures the expansion and flow of liquid refrigerant into the evaporator while there is a steep fall in pressure and temperature.

4-way valve

It is used to reverse the cooling circuit, which allows the heat pump to heat or cool

Control board

It is used to control the operation of the outdoor unit. Controls and optimizes the unit control function.

Defrost function

It is used to defrost frozen condensate in the winter months.

Anti-frozen

It is used for anti-freeze protection of the outdoor unit .

Technical data and documents for download

High seasonal efficiency reaches SCOP up to 4.9, which means that 1 kW of supplied electrical energy produces up to 4.9 kW of heat/cold. Find out more about other technical data.

loader-icon
  • High SCOP 4.9
  • Energy class A+++
  • Internet connection with a mobile application
  • Wide capacity range 6, 9, 12, 15, 19 kW
  • Suitable solution for low-temperature heating systems
  • Year-round operation with cooling option
  • Air-to-water monobloc
  • Heating with stable performance even at very low outdoor temperatures and DHW preparation in an external tank up to 55 °C
Model TCI06 TCI09 TCI12 TCI15 TCI19
Power supply/Refrigerant V/Hz/Ph 220-240/50/1-R32 380-420/50/3-R32
Feasible ambient temperature range -25~43
Min.water temperature in system heating/cooling 20/7
Circuit fuse Indoor/outdoor control board Indoor: 65TS/T15AL/250VOutdoor: 65TS/T25AL/250V Indoor: 65TS/T15AL/250V Outdoor: 51NM/10A/250V
Min.floor area for installation, operation and storage m2 7 17 28 56 58
Min.area pipeline m2 7 17 28 56 58
Max.operation by high pressure MPa 4.2
Max.operation by low pressure MPa 1.4
Refrigerant Typ/Quantity -/kg R32/0.9kg R32/1.4kg R32/1.8kg R32/2.55kg R32/2.6kg
Compressor Type/Quantity/System Double Rotaty – 1 Double Rotary – 1 Double Rotary – 1 Double Rotary – 1 Double Rotary – 1
Fan Quantity 1 1 1 2 2
Airflow m3/h 2500 3150 3150 6200 7000
Nominal output W 34 45 45 90 120
Noise level Indoor/Outdoor dB(A) 44/52 44/53 44/52 44/59 44/61
Water side heat exchanger Type Doskový výmenník tepla Doskový výmenník tepla Doskový výmenník tepla Doskový výmenník tepla Doskový výmenník tepla
Water pressure drop kPa 26 26 26 26 26
Pipping connection Inch G1″ G1″ G1″ G1-1/4″ G1-1/4″
Allowable Water Flow Min./Nominal./Max. L/S 0.21/0.29/0.35 0.26/0.43/0.52 0.34/0.57/0.68 0.43/0.71/0.85 0.55/0.92/1.1
Net dimension  L*D*H) Indoor unit mm 570X550X255 570X550X255 570X550X255 570X550X255 570X550X255
Outdoor unit mm 1010X370X700 1165X370X845 1165X370X845 1085X390X1450 1085X390X1450
Net Weight Indoor unit Kg 25 25 25 25 25
Outdoor unit Kg 65 78 85 120 140
Model ATTACK 6 ATTACK 9 ATTACK 12 ATTACK 15 ATTACK 19
Power Supply V/Hz 220-240/50 380-420/ 50
Phase connection phase 1 3
Max. heating capacity (1) kW 6,5 9,2 11,6 15,35 18,5
C.O.P (1) 4,61 4,38 4,3 4,78 4,47
Heating capacity Min./Max.(1) kW 3,5 / 6,5 4,3/9,2 5,5 / 11,6 6/15,35 9,2/18,5
Heating Power Input Min./Max.(1) W 758 / 1410 927/2097 1107 / 2683 1222/3209 1834/4142
C.O.P Min./Max.(1) 4,5 / 4,7 4,38/4,71 4,3 / 4,9 4,78/5,06 4,47/5,01
Max. heating capacity (2) kW 6 8,6 11,2 14,26 18,2
C.O.P (2) 3,46 3,37 3,45 3,64 3,6
Heating capacity Min./Max.(2) kW 3,15 / 6 3,9/8,6 4,9 / 11,2 5,6/14,26 8,5/18,2
Heating Power Input Min./Max.(2) W 943 / 1732 1162/2550 1401 / 3263 1551/3913 2248/4998
C.O.P Min./Max.(2) 3,34 / 3,56 3,37 / 3,58 3,3 / 3,5 3,64 / 3,82 3,6 / 3,82
Max. Cooling Capacity (3) kW 7,45 9,5 9,8 18,57 22,5
E.E.R (3) 4,05 4,23 3,9 3,78 3,58
Cooling Capacity Min./Max.(3) kW 6,22/7,45 6,7/9,5 7,2/9,8 7,23/18,57 8,5/22,5
Power input Min./Max.(3) W 1400/1863 1679/2242 1791/2510 D1334/4917 1660/6285
E.E.R Min./Max.(3) 4,05/4,45 4,0/4,6 4,0/3,8 3,78/5,42 3,58/5,12
Max. Cooling Capacity (4) kW 4,5 7,2 6,5 13 16
E.E.R (4) 2,7 2,8 2,7 2,96 2,85
Cooling capacity Min./Max.(4) kW 3,5/4,5 4,9/7,2 4,9 / 6,5 4,46/13 5,5/16
Power input Min./Max.(4) W 1330/1680 1451/2366 1358 / 2444 2592/4390 2970/5510
E.E.R Min./Max.(4) 2,5/2,74 2,8/3,1 2,6 / 3,5 2,96/3,29 2,85/3,2
Outdoor temperature operating range °C -25~43
Min.water temperature (Heating / Cooling) °C 20 / 7
Electrical fuses for control electronics Indoor unit: 65TS/T15AL/250VOutdoor unit: 65TS/T25AL/250V Indoor unit: 65TS/T15AL/250VOutdoor unit: 51NM/10A/250V
Min. floor area for installation, operation and storage m2 0,8 1,9 3,1 6,2 6,4
Max. operation by high pressure MPa 4,2
Max. operation by low pressure MPa 1,2
Compressor Type/Quantity Double Rotary – 1 Double Rotary – 1 Double Rotary – 1 Double Rotary – 1 Double Rotary – 1
Refrigerant Type / Weight – / kg R32 / 0,9kg R32 / 1,4kg R32 / 1,8kg R32 / 2,55kg R32 / 2,6kg
Fan – quantity pc 1 1 1 2 2
Fan – air flow m3/h 2500 3150 3150 6200 7000
Fan- nominal output W 34 45 45 90 120
Indoor/Outdoor unit dB(A) 44/52 44/53 44/52 44/55 44/59
Water Side Heat Exchanger Type Plate Heat Exchanger
Heat Exchanger – Water Pressure Drop kPa 26
Heat Exchanger – Piping connection inch G1″ G1-1/4″
Allowable Water FlowMin./Nominal/Max. l/s 0,21/0,29/0,35 0,26/0,43/0,52 0,34/0,57/0,68 0,43/0,71/0,85 0,55/0,92/1,1
Dimensions (L×D×H)Indoor unit mm 570x550x255
Dimensions (L×D×H)Outdoor unit mm 1010x370x700 1165x370x845 1085x390x1450
Weight indoor unit kg 25 25 25 25 25

Note: (1) Heating condition: Water inlet/outlet temperature: 30°C/35°C, Ambient temperature: DB 7°C/ WB 6°C;

(2) Heating condition: Water inlet/outlet temperature: 40°C/45°C, Ambient temperature: DB 7°C/ WB 6°C;

(3) Cooling condition: Water inlet/outlet temperature: 23°C/18°C, Ambient temperature: DB 35°C/ WB 24°C;

(4) Cooling condition: Water inlet/outlet temperature: 12°C/7°C, Ambient temperature: DB 35°C/ WB 24°C;

Technical parameters and specifications are subject to change

Accessories to the heat pump

By purchasing accessories, you can significantly help improve efficiency. Increasing efficiency, reducing fuel consumption, reducing the amount of tar and acids, extending service life – all this can be achieved with accessories.

loader-icon
The ATTACK AK INOX stainless steel tank ensures sufficient flow in the heat pump circuit and a certain accumulation of water for the defrosting system. The tank achieves a long service life thanks to the high-quality stainless steel material.
The stainless steel tank is ready to heat hot water even in the event of insufficient power or a failure of the hot water source. It contains an electric coil with a power of 3 kW, which can heat the water in the DHW tank independently of an external heat source.
Fan coil units are suitable for spaces where they provide a pleasant temperature all year round. The heat pump, as a source of heat and cold, can supply the fan coil with hot or cold water, which can be used during the summer to pleasantly cool the interior and during the winter to provide heat at low cost.

Ensuring comfortable temperature all year round

In addition to heating, the heat pump can also fully cool using fancoil units. Maintaining a pleasant room temperature is important for all household activities and a peaceful sleep.

Control the heat pump from any location

We provide a WIFI router along with access to the ATTACK Heating mobile application for the heat pump completely free of charge. You thus get a perfect overview of the current status and full control over the heat pump.

Heat-pump-attack-consumption en

Get a detailed overview of heat pump consumption

Subsidy program Green for Households

Take advantage of a great chance to get a new modern device for a family house with a subsidy. Request a price offer, and we will handle the entire process, including the subsidy, for you.

heat pump attack subsidy en

Choose a service partner

Creating a high-quality and prompt service network for our customers is very important to us. Our service partners thus provide prompt service assistance to every customer throughout the year.

We have a rich service network covered throughout the world

Related products